Features:
1. Continuous Cycle Automatic Feeding and Discharging System
● Uninterrupted Production:Through a rational material conveying path and control system, continuous material feeding and discharging is achieved in an atmospheric or vacuum environment, eliminating downtime, reducing repeated cleaning and replacement gas, and improving continuous operation and production efficiency.
● Intelligent Control System:Utilizing PLC control, combined with a touch screen or computer interface, enables precise control and monitoring of the entire process.
2. Rotational Oscillation Design
● Uniform Heating:The material rotates and oscillates at a specific speed within the furnace, ensuring uniform heating and avoiding localized overheating or underheating.
● Flexible Adjustment:The rotation speed and oscillation angle can be adjusted to achieve optimal heating results based on different process requirements.
3. Precise Temperature and Atmosphere Control
● PID Temperature Control System:Utilizing an advanced PID controller, precise temperature control is achieved, ensuring temperature stability and consistency during the heating process.
● Multiple Atmosphere Options:Supports operation in inert gases (such as nitrogen and argon), reducing gases (such as hydrogen), or mixed gas environments to prevent sample oxidation or other chemical reactions.
4. Optional Analytical Instruments:
● Oxygen Analyzer:Real-time monitoring of oxygen concentration in the atmosphere to ensure a non-oxidizing environment.
● Dew Point Analyzer:Monitors moisture content in the atmosphere to prevent excessive humidity from affecting product quality.
5. Safety and Maintenance
● Overtemperature Protection:Built-in overtemperature protection automatically cuts off power when the temperature rises abnormally, preventing equipment damage.
● Emergency Stop Button:A clearly defined emergency stop button ensures operator safety.
● Regular Maintenance Reminder:The system can set regular maintenance reminders to help users perform timely equipment maintenance and extend its service life.
6. Data Recording and Analysis
● Real-time Monitoring:The built-in data acquisition system records key parameters such as temperature, atmosphere composition, and rotation speed in real time for subsequent analysis.
● Data analysis software:Provides professional data analysis software that supports automatic report generation and allows data to be exported for in-depth analysis.
|
Equipment Model |
NBD-RT1200-150T2D2F2L-N |
|
Power Supply |
AC380V 50/60HZ |
|
Rated Power |
13KW |
|
Heating Element |
HRE Alloy Resistance Wire |
|
Furnace Temperature Control Accuracy |
±1℃ |
|
Temperature Sensor |
R-Type Thermocouple, Corundum Tube φ3 × 100 mm, Wire Diameter 0.4 mm |
|
Rated Sintering Temperature |
≤1150℃ |
|
Recommended Heating Rate |
≤10℃ / min |
|
Furnace Temperature Zone Dimensions |
φ200 × 590 mm Single Temperature, Dual Control |
|
Furnace Tube Dimensions |
Reduced Quartz Tube φ60 × 4 × 1200 mm, Center φ160 × 4 × 550 / 374 mm Internal Connection: Four 155 × 3 × 30 mm quartz plate, effective volume 2L
|
|
Furnace tube inclination angle |
≤31° |
|
Furnace tube speed |
0.1-12.6 rpm (adjustable) |
|
Furnace tube pressure resistance |
≤0.12 MPa (absolute pressure) |
|
Feed tank capacity |
4L |
|
Collection tank capacity |
4L |
|
Vacuum pump model |
DRV10 KF25 interface, pumping rate 9.9 m³/h, motor speed 1440 rpm |
|
System vacuum |
≤10pa |
|
Vacuum flowmeter 1 |
0.3-3L / min |
|
Vacuum flowmeter 2 |
0.5-8L / min |
|
Oxygen content detection |
0-100 PPM (trace), measurement accuracy ≤±2%FS, resolution 0.1 PPM |
|
Water content
(dew point detection)
|
Standard model -80°C to +20°C, measurement accuracy ≤±2°C (Below -60°C)
Resolution 0.1°C, display in PPM units (can be switched)
|
|
Furnace Dimensions |
L 2130 mm × H 2300 mm × D 880 mm |
|
Furnace Weight |
Approximately 350 kg |